News & Updates

Return to News List

Time for an upgrade! 11.6.0

|

REALITi 360 Version 11.6.0 is here!

Enhancements

Multiple Screens

  • Enabled unit measurements' conversion in IBP and NIBP of the following monitors: Zoll R, Philips MRx, Schiller Defigard Touch7, Generic Monitor, Generic Defib, Generic Wave, Generic Numerics, GE Carescape B850, Philips IntelliVue MX800, and WelchAllyn Connex
  • Monitors that do not support the conversion to unit cmH2O will remain as mmHG
  • Enabled Pacer Settings' Default Output and Rate for Zoll Propaq MD, Zoll X, Schiller Defigard Touch 7, and Tempus LS
  • Changed Pacer Settings' Remember Last Output and Rate for Zoll Propaq MD, Zoll R, Zoll X, Schiller Defigard Touch 7, and Tempus LS
  • Resolved the issue where the ECG waveform did not update when the new waveform matched the one from the previously loaded scenario

Capnostream 35

  • Resolved crash issue on starting Capnostream 35

Corpuls 3/3T

  • Metronome now reverts to the original configured ratio
  • Fixed issue with Start Analysis being played just after powering on, no delay
  • Metronome now resets to Adult 30:2 when C3/C3T is powered off

Hamilton T1

  • F Total b/min now appears as an integer in Alarms and in the Monitoring section

Lifepak 15

  • Display overlap resolved on NIBP countdown timer and MAP
  • Enabled reset on contrast when the monitor is turned off
  • Home and high-contrast Sunvue buttons fixed, where the lower portion was unresponsive to clicks
  • Resolved crash issue when changing back from high contrast Sunvue display to color display
  • Metronome stabilized
  • Enabled correct state for CPR button when switching from AED to manual defibrillator

Revel Vent

  • Resolved audible tone looping after swiping from left to exit the ventilator

Schiller Defigard/Touch 7

  • Enabled flashing alarm light and parameter field flashes in the secondary Pulse field when limits are exceeded
  • Implemented alarm light flash for HR
  • Added heart icon in the second Pulse parameter field
  • Fixed primary Pulse background to blue when changing from HR to Pulse
  • Secondary Pulse now changes to dashes when the Control’s finger probe is off
  • Resolved issue where HR, SpO2, and Pulse are not flashing in both alarm light and parameter fields when limits are exceeded
  • Primary Pulse now reverts to the HR field when the AUTO source is revealed
  • Enhanced Schiller Defigard Touch7 to ensure that adjusting the CO2 unit measurements no longer alters NIBP values

Zoll R

  • Eliminated the "NIBP MEAS ABORTED" alert that appeared whenever adjustments were made to the NIBP value in the Control Parameter Settings

Contatta iSimulate

Contattaci e scopri tutte le funzionalità dei prodotti iSimulate